When looking for a Parker PRDM valve replacement, the first step is not simply finding a valve with a similar appearance or series name. PRDM valves are available in different configurations, including different pressure-reducing ports, adjustment methods, mounting sizes, and pressure ranges.
For maintenance and procurement teams, a replacement should therefore be checked against the original part number, hydraulic function, mounting interface, pressure range, and connection details before an order is placed.
This guide explains what to check when sourcing a Parker PRDM replacement and shows several PRDM models available from Naboer as practical examples. You can also browse Parker PRDM valve models available from Naboer when comparing configurations.

Parker PRDM is a series of direct-operated pressure reducing valves used in hydraulic circuits to reduce pressure in a selected section of the system. Parker documentation describes PRDM valves as sandwich valves that can be configured for pressure reduction at the P, A, or B port.
The series includes different mounting sizes and adjustment options. For example, PRDM2 models use an NG06 / CETOP 03 mounting interface, while the PRDM3 range uses a larger NG10 / CETOP 5 configuration.
For technical reference, buyers can review the Parker PRDM technical catalog before comparing a replacement.
The important point is that “PRDM” alone is not enough to identify a replacement. The complete model designation and application requirements still need to be checked.
A practical replacement review can start with five key items.
Record the full part number from the existing valve, nameplate, maintenance record, or equipment documentation.
For example, Naboer's product range includes PARKER PRDM2PP16LVG17, listed as a direct-operated pressure reducing valve with the part number PRDM2PP16LVG. It is an NG06 / CETOP 03 valve designed for pressure reduction in port P, with a 160 bar pressure range and G 1/4 gauge port. View PRDM2PP16LVG17 product details.
A partial model number can leave important configuration details unresolved, so the complete identification should be used in the RFQ whenever possible.
PRDM valves can be configured for pressure reduction in different ports.
This matters when comparing a replacement because a valve intended for P-port pressure reduction should not automatically be treated as equivalent to an A-port or B-port configuration.
For example, PARKER PRDM2AA16KVG is listed for pressure reduction in port A. It uses an NG06 / CETOP 03 mounting interface, has a 160 bar pressure control range, and uses a turning knob for pressure adjustment. View the PRDM2AA16KVG product.
This makes the port configuration an important part of the replacement check, rather than simply matching the PRDM series name.
Two PRDM valves can have similar basic functions but different adjustment configurations.
For example:
PRDM2PP16LVG17 uses a cylinder-lock adjustment configuration.
PRDM2PP16SVG15 uses a hexagon-socket adjustment.
PRDM2AA16KVG uses a turning knob.
The PARKER PRDM2PP16SVG15 is also an NG06 / CETOP 03 valve for pressure reduction in port P, with a 160 bar pressure range and G 1/4 gauge port. View PRDM2PP16SVG15 product details.
When replacing an installed valve, the adjustment method can matter for maintenance access and the way the equipment is configured.
Mounting size, port configuration, gauge connection, and installation arrangement should be compared with the existing hydraulic assembly.
For PRDM2 models, Parker documentation identifies the mounting pattern as NFPA D03 / CETOP 3 / NG6. However, a matching mounting size does not by itself establish that two complete valve configurations are interchangeable.
The buyer should compare:
Mounting size and pattern
Pressure-reducing port
Gauge port
Adjustment configuration
Pressure range
Seal material where relevant
Hydraulic circuit requirements
Existing equipment documentation
For additional Parker hydraulic valves, buyers can also browse Naboer's Parker Valve category when comparing related valve models.
If you already know that the required valve belongs to the PRDM family, the Parker PRDM valve product listing provides another starting point for comparing available models and configurations.

A product-level comparison is more useful than evaluating a replacement only by series name.
| Model | Function | Mounting | Pressure Range | Adjustment |
|---|---|---|---|---|
| PRDM2PP16LVG17 | Reduction in port P | NG06 / CETOP 03 | 160 bar | Cylinder lock |
| PRDM2PP16SVG15 | Reduction in port P | NG06 / CETOP 03 | 160 bar | Hexagon socket |
| PRDM2AA16KVG | Reduction in port A | NG06 / CETOP 03 | 160 bar | Turning knob |
These examples show why the full model number is important. The first two models have the same general P-port pressure-reducing function and mounting size, but their adjustment configurations differ. The third model changes the pressure-reducing port to A and therefore requires a different application check.
The specifications above are based on the corresponding Naboer product pages. Final replacement decisions should still be based on the original equipment documentation and the requirements of the hydraulic system.
A simple procurement workflow can help avoid unnecessary substitutions.
Record the complete part number, photos of the marking, equipment model, and available technical documentation.
Confirm whether the valve reduces pressure in port P, A, or B and identify the required operating range.
Check mounting size, gauge connection, hydraulic ports, and other installation requirements.
Review adjustment type, seal material, pressure range, and other model-specific characteristics.
Ask the supplier to provide the exact offered part number, technical datasheet, applicable drawings, lead time, quantity, and quotation conditions.
If the proposed item differs from the installed valve, the difference should be reviewed before purchase or installation. For hydraulic maintenance work, site procedures for controlling hazardous energy should also be followed. The OSHA guidance on Control of Hazardous Energy provides general information on lockout/tagout requirements.
A clear RFQ makes it easier for suppliers to respond with comparable information.
Include:
Original Parker part number
Equipment or hydraulic system application
Required PRDM series and configuration, if known
Pressure range
Pressure-reducing port
Mounting interface
Gauge port connection
Adjustment requirements
Quantity
Required documentation
Target delivery date
Shipping destination
Instead of asking only, “Do you have a Parker PRDM replacement?”, provide the existing part number and technical requirements.
This gives the supplier enough information to identify a specific product and reduces the chance of receiving a quotation based only on a similar series name.
A similar-looking hydraulic valve is not automatically a suitable replacement.
For example, two valves may both use an NG06 / CETOP 03 mounting interface but differ in the controlled port or adjustment configuration. Likewise, two products may share the PRDM family name while having different pressure ranges or options.
For this reason, a cross-reference should be treated as a starting point for technical comparison, not as automatic approval.
If the original part number is unavailable, provide photographs, equipment information, hydraulic drawings, and as much specification data as possible when requesting a quotation.
Buyers who are still identifying the correct model can also review Naboer's available Parker PRDM valve models before sending an RFQ.

Not necessarily. The PRDM series identifies a product family, but the complete configuration still needs to be checked. Pay particular attention to port function, mounting size, pressure range, adjustment type, and connection details.
The complete part number is the best starting point. If it is unavailable, provide the valve marking, photographs, equipment model, hydraulic circuit information, mounting dimensions, and known operating requirements.
They share the PRDM2 P-port pressure-reducing configuration and 160 bar pressure range, but their adjustment configurations differ. Naboer lists the PRDM2PP16LVG17 with cylinder-lock adjustment and the PRDM2PP16SVG15 with hexagon-socket adjustment. The exact replacement decision should therefore consider the installed application and required configuration.
You can provide the complete part number and application requirements through the Naboer contact page. For a replacement request, including the original model number and any available technical information can help the supplier identify the relevant product more efficiently.
A Parker PRDM valve replacement should be evaluated from the complete configuration rather than the PRDM family name alone. Check the original part number, pressure-reducing port, mounting interface, pressure range, adjustment method, and connection requirements before comparing suppliers or alternatives.
For example, Naboer's PRDM2PP16LVG17, PRDM2PP16SVG15, and PRDM2AA16KVG illustrate how different PRDM configurations can serve different hydraulic requirements.
For a quotation, provide the complete model number whenever possible and ask the supplier to confirm the offered part identity and supporting documentation. This creates a clearer basis for procurement and subsequent engineering review.
Contact:Sherry Zhou
WhatsApp/Mobile:
+86-189 17398894
E-mail:sherry.z@naboer.com.cn
Contact:JiaWen Zhou
Phone:+86-199 56011825
E-mail:zjw@naboer.com.cn
Add:Room 2103, 21st Floor, Hongtai Center, Intersection of Jinxiu Avenue and Guangxi Road, Baohe District, Hefei City, Anhui Province, China